MENU GENERALE    MAIN MENU 

THELEPHONE CABLES

HAR CABLES

5E LAN CABLES

SECURITY CABLES

CONTROL CABLES

COAXIAL CABLES


FLAT CABLES
H03VVH2-F  H05VVH2-F  Loudspeaker type

H05 VVH6-F and H07 VVH6-F
5PVC-insulated flat flexible cable according to VDE 0281 ( CEI 20-25 / CEI - UNEL 00725 )
APPLICATIONS

These PVC-insulated flat flexible cables are used for installation as power and control cables for cable tracks and carriers, transport systems, tool machinery, in particular for hoisting equipment, lifts, crane and container bridges and in all circumstances in which the cable is subjected to severe bending and continuous movement in one plane only. These flat flexible cables are suitable for installation in dry, moist and wet rooms. These cables are not suitable for outdoor applications or ambient air temperatures below 0°C or above +40°C.

Characteristic features

• The reduced dimension means that these flat flexible cables are space-saving compared to round flexible cables.
• Considerably smaller bending radius than for round flexible cables.
• Multiple bundling of flat flexible cables possible.
• A uniform loop is formed in the axial direction such that no excess lay-up or the cores can occur.

Notes

• Free-hanging lengths of 35 m or traversing speed of 1,6 m/s should not be exceeded for the above-mentioned machinery.
• The cables must be rolled up and suspended such that no twisting or kinks occur.
• The cables should be freely suspended, secured at one end, in the lift shaft for several days before being installed.
• These should be no sharp edges in the lift shaft behind the moved cables such as supports between front and rear side of multiple-lift shafts which could damage the cables.

Durability

• Chemical resistance properties of PVC-refer also to the Table of Technichal Guidelines

CABLE DESIGN
  • Construction designed according to VDE 0281 part 403 and part 404

  • Conductor : plain Cu wires, flexible

  • Construction of conductor : according to VDE 0295 Class 5 and conductor IEC 228 Class 5
    Insulation : Core insulation of PVC, compound type T12 according to VDE 0207 part 4

  • Core identification : according to VDE 0293, single colour up to 5 cores, black cores with sequentil numbering imprint in white for 6 or more cores

  • Protective earth : conductor: green-yellow

  • Core configuration : cores parallel and adiacent

  • Sheath* : Sheath material of PVC, compound type TM2 according to VDE 0207 part 5 Sheath wall thickness: according to the table 3, columns 8 to 10 in VDE 0281 part 403 and part 404

  • Sheath colour : black as the preferred colour or grey

* Single layer sheath
Note Other core configurations and cross sections manufactured upon request.

Technical data
  • Conductor resistance : according to VDE 0295 Class 5 and IEC at 20°C 228 Class 5 for flexible conductors

  • Temperature at the conductor max : + 70 °C in operation + 150°C in the event of a short circuit

  • Insulation resistance at 20°C min : 20 M W • km

  • Rated voltage
    H05VVH6 U 0 /U : 300 / 500 V
    H07VVH6 U 0 /U : 450 / 750 V

  • Test voltage AC, 50 Hz
    H05VVH6 : 2500 V
    H07VVH6 : 3000 V

  • Breackdown voltage min : 6000 V

  • Bending radius : 10 x cable thickness

  • Temperature range
    mobile : -5°C to +70°C
    fixed : -40°C to +70°C

  • Radiation resistance : 80 Mrad ( 80 x 106 cJ/kg )

  • Testing according to DIN VDE 0472 and IEC regulation
    Flame test : test class B according to VDE 0472 part 804, IEC 332-1

  • PVC characteristics : self-extinguishing and flame-retardant

DIMENSIONS
No. of
conductors nominal
cross section n. x mm2
Approx. outer
dimensions of cable
Height x width mm
Copper weight
kg / km
Approx. cable
weight
H05VVH6-F
4 G 0,75
8 G 0,75
12 G 0,75
18 G 0,75
24 G 0,75
4,2 x 12,6
4,2 x 23,2
4,2 x 33,8
4,2 x 50,2
4,2 x 65,6
29
58
86
130
172
100
178
265
385
492
H05VVH6-F
4 G 1
5 G 1
8 x 1
8 G 1
12 G 1
18 G 1
24 G 1
4,4 x 13,4
4,4 x 15,5
4,4 x 24,8
4,4 x 24,8
4,4 x 36,2
4,4 x 53,8
4,4 x 70,4
38
48
77
77
115
208
230
108
129
207
207
305
455
588
H07VVH6-F
4 G 1,5
4 x 1,5
5 G 1,5
7 G 1,5
8 G 1,5
8 x 1,5
10 G 1,5
10 x 1,5
12 G 1,5
12 x 1,5
18 G 1,5
24 G 1,5
5,2 x 14,5
5,2 x 14,5
5,2 x 17,5
5,2 x 25,3
5,2 x 25,3
5,2 x 25,3
5,2 x 27,3
5,2 x 27,3
5,2 x 40,8
5,2 x 40,8
5,2 x 61,8
5,2 x 83
58
58
72
101
115
115
144
144
173
173
259
346
135
135
162
234
257
257
325
325
390
390
668
822
H07VVH6-F
4 G 2,5
5 G 2,5
7 G 2,5
8 G 2,5
10 G 2,5
12 G 2,5
24 G 2,5
5,9 x 17,5
5,9 x 21,1
5,9 x 31,1
5,9 x 33,1
5,9 x 42,6
5,9 x 49,1
5,9 x 102,0
99
120
168
192
240
288
480
193
238
344
375
518
565
1224
H07VVH6-F
4 G 4
5 G 4
7 G 4
6,9 x 20,0
6,9 x 26,0
6,9 x 35,3
154
192
269
273
282
485
H07VVH6-F
4 G 6
5 G 6
7 G 6
7,4 x 22,0
7,4 x 31,0
7,4 x 43,0
230
288
403
360
532
753
H07VVH6-F
4 G 10
5 G 10
9,3 x 27,6
11,0 x 37,5
348
480
584
1125
H07VVH6-F
4 G 16
5 G 16
11,1 x 34,4
11,2 x 43,5
614
768
616
770

Core coulours

4 cores : green - yellow, black, blue, brown
5 cores : green - yellow, black, blue, brown, black
6 and more cores : green - yellow, black, blue, with sequential numbering imprint in white

Note:

 Other core configurations and cross sections manufactured upon request

MENU

 

H05VVH2-F
CEI 20 -20 - UNEL 35749 ( Nominal Tension :300 - 500 V - Test Voltage: 2000 V )
Approx. outer
dimensions of cable
Height x width mm
No. of conductors nominal cross section n. x mm2 Ø max Wires
mm
Insulation
thickness
Sheath
thickness
Outer
diameter
Electrical
resistance
to 20 °C
Insulation
resistance
to 70 °C
Approx. cable
weight
medio mm min mm medio mm min mm medio mm min mm max 
W / km
min 
W / km
kg /  km
3,30 X 5,40
3,50 X 5,80
2 X 0,5
2 X 0,75
0,21
0,21
0,5
0,5
0,35
0,35
0,6
0,6
0,41
0,41
3,0X4,8
3,2X5,2
3,6X6,0
3,9X6,4
39,0
26,0
0,012
0,010
24
32

MENU

 

H03VVH2-F
CEI 20 -20 - UNEL 35749 ( Nominal Tension :300 - 300 V - Test Voltage: 2000 V )
Approx. outer
dimensions of cable
Height x width mm
No. of conductors nominal cross section n. x mm2 Ø max Wires
mm
Insulation
thickness
Sheath
thickness
Outer
diameter
Electrical
resistance
to 20 °C
Insulation
resistance
to 70 °C
Approx. cable
weight
medio mm min mm medio mm min mm medio mm min mm max 
W / km
min 
W / km
kg /  km
4,2 X6,6 2 X 0,75 0,21 0,6 0,44 0,8 0,58 3,8X6,0 5,2X7,6 26,0 0,011 39

MENU

 

Loudspeaker type
 Nominal Tension :300 - 300 V - Test Voltage: 2000 V )
Section
mm2
Copper weight
kg/km
Wires
Diam.
mm
Approx. Weight
kg/km
( N ) YFAZ 300/300 V
2 x 0,5
2 x 0,75
2 x 1.0
2 x 1,5
2 x 2,5
2 x 4
10
15
20
30
50
80
16 x 0,21
24 x 0,21
30 x 0,21
30 x 0,26
50 x 0,26
56 x 0,31
2,1 x 4,4
2,3 x 5,0
2,6 x 5,5
2,8 x 6,0
3,6 x 7,5
4,6 x 9,5
16
22
28
37
6
101
LFZ-XY 300/300 V
2 x 1,5
2 x 2,5
2 x 4,0
2 x 6,0
2 x 10,0
30
50
80
120
200
189 x 0,10
322 x 0,10
513 x 0,10
783 x 0,10
1292 x 0,10
3,1 x 6,5
3,6 x 7,5
5,0 x 10,2
6,1 x 12,5
7,0 x 15,0
41
61
104
156
250

MENU