MENU GENERALE MAIN MENU |
|||||
FLAT CABLES
H03VVH2-F
H05VVH2-F
Loudspeaker type
|
|
|
|
H05 VVH6-F and H07 VVH6-F 5PVC-insulated flat flexible cable according to VDE 0281 ( CEI 20-25 / CEI - UNEL 00725 ) |
| APPLICATIONS |
|
These PVC-insulated flat flexible cables are used for installation as power and control cables for cable tracks and carriers, transport
systems, tool machinery, in particular for hoisting equipment, lifts, crane and container bridges and in all circumstances in which the
cable is subjected to severe bending and continuous movement in one plane only. These flat flexible cables are suitable for
installation in dry, moist and wet rooms. These cables are not suitable for outdoor applications or ambient air temperatures below 0°C or
above +40°C. |
| CABLE DESIGN |
* Single layer sheath |
|
|
| Technical data |
|
| DIMENSIONS |
| No. of conductors nominal cross section n. x mm2 |
Approx. outer dimensions of cable Height x width mm |
Copper
weight kg / km |
Approx. cable weight |
| H05VVH6-F | |||
| 4 G 0,75 8 G 0,75 12 G 0,75 18 G 0,75 24 G 0,75 |
4,2 x 12,6 4,2 x 23,2 4,2 x 33,8 4,2 x 50,2 4,2 x 65,6 |
29 58 86 130 172 |
100 178 265 385 492 |
| H05VVH6-F | |||
| 4 G 1 5 G 1 8 x 1 8 G 1 12 G 1 18 G 1 24 G 1 |
4,4 x 13,4 4,4 x 15,5 4,4 x 24,8 4,4 x 24,8 4,4 x 36,2 4,4 x 53,8 4,4 x 70,4 |
38 48 77 77 115 208 230 |
108 129 207 207 305 455 588 |
| H07VVH6-F | |||
| 4 G 1,5 4 x 1,5 5 G 1,5 7 G 1,5 8 G 1,5 8 x 1,5 10 G 1,5 10 x 1,5 12 G 1,5 12 x 1,5 18 G 1,5 24 G 1,5 |
5,2 x 14,5 5,2 x 14,5 5,2 x 17,5 5,2 x 25,3 5,2 x 25,3 5,2 x 25,3 5,2 x 27,3 5,2 x 27,3 5,2 x 40,8 5,2 x 40,8 5,2 x 61,8 5,2 x 83 |
58 58 72 101 115 115 144 144 173 173 259 346 |
135 135 162 234 257 257 325 325 390 390 668 822 |
| H07VVH6-F | |||
| 4 G 2,5 5 G 2,5 7 G 2,5 8 G 2,5 10 G 2,5 12 G 2,5 24 G 2,5 |
5,9 x 17,5 5,9 x 21,1 5,9 x 31,1 5,9 x 33,1 5,9 x 42,6 5,9 x 49,1 5,9 x 102,0 |
99 120 168 192 240 288 480 |
193 238 344 375 518 565 1224 |
| H07VVH6-F | |||
| 4 G 4 5 G 4 7 G 4 |
6,9 x 20,0 6,9 x 26,0 6,9 x 35,3 |
154 192 269 |
273 282 485 |
| H07VVH6-F | |||
| 4 G 6 5 G 6 7 G 6 |
7,4 x 22,0 7,4 x 31,0 7,4 x 43,0 |
230 288 403 |
360 532 753 |
| H07VVH6-F | |||
| 4 G 10 5 G 10 |
9,3 x 27,6 11,0 x 37,5 |
348 480 |
584 1125 |
| H07VVH6-F | |||
| 4 G 16 5 G 16 |
11,1 x 34,4 11,2 x 43,5 |
614 768 |
616 770 |
|
Core coulours 4 cores : green - yellow, black, blue, brown |
Note:
Other core configurations and cross sections manufactured upon request |
||
|
|
|
H05VVH2-F CEI 20 -20 - UNEL 35749 ( Nominal Tension :300 - 500 V - Test Voltage: 2000 V ) |
| Approx. outer dimensions of cable Height x width mm |
No. of conductors nominal cross section n. x mm2 | Ø max
Wires mm |
Insulation thickness |
Sheath thickness |
Outer diameter |
Electrical resistance to 20 °C |
Insulation resistance to 70 °C |
Approx. cable weight |
|||
| medio mm | min mm | medio mm | min mm | medio mm | min mm | max W / km |
min W / km |
kg / km | |||
| 3,30 X 5,40 3,50 X 5,80 |
2 X 0,5 2 X 0,75 |
0,21 0,21 |
0,5 0,5 |
0,35 0,35 |
0,6 0,6 |
0,41 0,41 |
3,0X4,8 3,2X5,2 |
3,6X6,0 3,9X6,4 |
39,0 26,0 |
0,012 0,010 |
24 32 |
|
|
|
H03VVH2-F CEI 20 -20 - UNEL 35749 ( Nominal Tension :300 - 300 V - Test Voltage: 2000 V ) |
| Approx. outer dimensions of cable Height x width mm |
No. of conductors nominal cross section n. x mm2 | Ø max
Wires mm |
Insulation thickness |
Sheath thickness |
Outer diameter |
Electrical resistance to 20 °C |
Insulation resistance to 70 °C |
Approx. cable weight |
|||
| medio mm | min mm | medio mm | min mm | medio mm | min mm | max W / km |
min W / km |
kg / km | |||
| 4,2 X6,6 | 2 X 0,75 | 0,21 | 0,6 | 0,44 | 0,8 | 0,58 | 3,8X6,0 | 5,2X7,6 | 26,0 | 0,011 | 39 |
|
|
|
Loudspeaker type Nominal Tension :300 - 300 V - Test Voltage: 2000 V ) |
| Section mm2 |
Copper weight kg/km |
Wires N° |
Diam. mm |
Approx. Weight kg/km |
| ( N ) YFAZ 300/300 V | ||||
| 2 x 0,5 2 x 0,75 2 x 1.0 2 x 1,5 2 x 2,5 2 x 4 |
10 15 20 30 50 80 |
16 x 0,21 24 x 0,21 30 x 0,21 30 x 0,26 50 x 0,26 56 x 0,31 |
2,1 x 4,4 2,3 x 5,0 2,6 x 5,5 2,8 x 6,0 3,6 x 7,5 4,6 x 9,5 |
16 22 28 37 6 101 |
| LFZ-XY 300/300 V | ||||
| 2 x 1,5 2 x 2,5 2 x 4,0 2 x 6,0 2 x 10,0 |
30 50 80 120 200 |
189 x 0,10 322 x 0,10 513 x 0,10 783 x 0,10 1292 x 0,10 |
3,1 x 6,5 3,6 x 7,5 5,0 x 10,2 6,1 x 12,5 7,0 x 15,0 |
41 61 104 156 250 |