MENU GENERALE    MAIN MENU 

THELEPHONE CABLES

HAR CABLES

5E LAN CABLES

CONTROL CABLES

FLAT CABLES

COAXIAL CABLES


SECURITY CABLES
Combined Cables for CCTV - Cavi Combinati per CCTV
Fireproof Cables - Cavi Antifuoco
Power Cables and Special Cables - Cavi Potenza e Cavi Speciali
RG 174 A/U - RG 58 C/U - RG 59 B/U - Mini RG 59 - MiniCoax

 

Alarm Cables
Although the use of cables in the security sector presents complex and diverse challenges, FTC, thanks to our specialised experience in this specific sector, is able to satisfy any connection requirement guaranteeing maximum operational reliability. We offer our clients two versions of our alarm cable:
• Traditional security cable both multipolar and combined with external sheathing and PVC conductors in either rigid or flexible versions, produced to meet the required IEC, CEI, VDE and NFC standards.
• Rigid or flexible LSZH security cable, both multipolar and combined with conductors and external sheathing in LSZH, zero halogen with low emission of toxic gas and smoke, produced to meet the required IEC, CEI, VDE and NFC standards and conforming to every regulation necessary for the installation of cables in public places, museums, hotels, hospitals, etc.

Cavi Allarme
La FTC, visto che l’impiego di cavi nel settore della Sicurezza presenta le problematiche fra le più complesse e diversificate, grazie all’esperienza nel settore specifico é in grado di soddisfare qualunque esigenza di connessione garantendo un’estrema affidabilità di funzionamento, propone ai suoi Clienti il Cavo d’allarme in due versioni:
• Cavo di sicurezza tradizionale sia multipolare che combinato con guaina e conduttori in PVC, sia rigido che flessibile, prodotto secondo le relative norme IEC - CEI - VDE - NFC.
• Cavo di sicurezza LSZH nella versione rigida e flessibile, sia multipolare che combinato con conduttori e guaina esterna in materiale LSZH, zero alogeno con bassa emissione di gas e fumi tossici, prodotto secondo le relative norme IEC - CEI - VDE - NFC e che risponde a tutte le prescrizioni necessarie all’installazione dei cavi nei locali pubblici, musei, hotels, ospedali ecc.

Type
Section / Sezione  *
Core / Conduttore
mm   *
Insulation / Isolamento
mm  *
Outside diam. / Diametro Totale
* ( mm )
 ( *Nominal value / Valori Nominali ) 300 / 300 V 450 / 750 V 0,6 / 1 KV
PVC / PVC 

2 x 0,22
4 x 0,22
6 x 0,22
8 x 0,22
10 x 0,22
12 x 0,22
2 x 0,22 +2 x 0,50
4 x 0,22 +2 x 0,50
6 x 0,22 +2 x 0,50
8 x 0,22 +2 x 0,50
10 x 0,22 +2 x 0,50
12 x 0,22 +2 x 0,50
14 x 0,22 +2 x 0,50
16 x 0,22 +2 x 0,50
20 x 0,22 +2 x 0,50
2 x 0,22 +2 x 0,75
4 x 0,22 +2 x 0,75
6 x 0,22 +2 x 0,75
8 x 0,22 +2 x 0,75
10 x 0,22 +2 x 0,75
12 x 0,22 +2 x 0,75
14 x 0,22 +2 x 0,75
16 x 0,22 +2 x 0,75
20 x 0,22 +2 x 0,75
4 x 0,6
6 x 0,6
8 x 0,6
10 x 0,6
12 x 0,6
14 x 0,6

 

7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
1 X 6 / 10
1 X 6 / 10
1 X 6 / 10
1 X 6 / 10
1 X 6 / 10
1 X 6 / 10

0,23
0,23
0,23
0,23
0,23
0,23
0,30 /0,23
0,30 /0,23
0,30 /0,23
0,30 /0,23
0,30 /0,23
0,30 /0,23
0,30 /0,23
0,30 /0,23
0,30 /0,23
0,35 /0,23
0,35 /0,23
0,35 /0,23
0,35 /0,23
0,35 /0,23
0,35 /0,23
0,35 /0,23
0,35 /0,23
0,35 /0,23
0,25
0,25
0,25
0,25
0,25
0,25

3,3
3,5
4,2
4,6
5,2
5,4
4,1
4,4
5,2
5,4
5,8
5,9
6,3
6,6
7,1
4,8
5
5,4
5,8
6,2
6,4
6,6
6,9
7,8
4,2
4,8
5
5,9
6,1
6,4

3,6
4,2
5
5,5
6
6,6
5
5,5
5,8
6,2
6,6
7
7,5
8,1
8,5
5,5
5,8
6
6,5
6,8
7
7,3
7,7
8,6

3,8
5
5,5
6
6,5
7,2
5,5
6
6,5
7
7,6
8
8,4
9
9,8
6
6,7
7,1
7,3
8,1
8,5
8,9
9,5
10,6

LSZH
Type
Section / Sezione *
Core / Conduttore
mm  *
Insulation / Isolamento
mm  *
Outside diam. / Diametro Totale
* ( mm )
 ( *Nominal value / Valori Nominali ) 300 / 300 V 450 / 750 V 0,6 / 1 KV
4 x 0,22
6 x 0,22
8 x 0,22
10 x 0,22
4 x 20 AWG
6 x 20 AWG
8 x 20 AWG
10 x 20 AWG
7 x 0,20
7 x 0,20
7 x 0,20
7 x 0,20
5 / 10
5 / 10
5 / 10
5 / 10
0,23
0,23
0,23
0,23
0,25
0,25
0,25
0,25
3,3
3,5
4,2
4,6
4,2
4,8
5
5,9
3,6
4,2
5
5,5
3,8
5
5,5
6

MENU

 

Combined Cables for CCTV
Our combined cables are produced according to the technical specifications required by the Institutes of Telesurveillance and the product range that FCT can supply at currently manufactu-red standards is as follows:
Cavi Combinati per CCTV
I nostri cavi combinati sono prodotti secondo le specifiche tecniche richieste dagli Istituti di Telesorveglianza e la gamma che la FCT può offrire negli standards attualmente prodotti é la seguente:

Mini Rg 59 + ( 2 x 0,75 + 2 x 0,22 )
MiniCoax + ( 2 x 0,75 + 2 x 0,22 )
Mini Rg 59 + MiniCoax + ( 2 x 0,75 + 2 x 0,22 )
Mini Rg 59 + ( 2 x 0,75 + 4 x 0,22 )
MiniCoax + ( 2 x 0,75 + 4 x 0,22 )
Mini Rg 59 + MiniCoax + ( 2 x 0,75 + 4 x 0,22 )

MiniCoax + 2 x 0,75
Mini Rg 59 + 2 x 0,50
Mini Rg 59 + ( 2 x 0,50 + 2 x 0,22 )
Special Combi TPHQ6 2 x 0,75 + 2 ( 2 x 0,22 + Al ) AL
Mini Rg 59 + 2 x 0,75
Mini Rg 59 + 2 x 0,50

MENU

 

Fireproof Cables
FTC can cater to clients’ needs in producing security cables which are fire resistant for use in firefighting plants, both with copper-mica and copper sheet shielding and fibreglass covering. These cables are produced to work between 30 and 180 minutes in the presence of fire.
Cavi Antifuoco
FTC é in grado di produrre, su richiesta del Cliente, cavi di sicurezza resistenti al fuoco per centrali antincendio, prodotti sia con rame-mica e sia con schermatura con foglio di rame e ricopertura in fibra di vetro. Questi cavi sono prodotti, secondo la tipologia, per funzionare da 30 a 180 minuti in ambienti con presenza di fuoco.

MENU

 

Power Cables and Special Cables
FTC can supply the Security Market with a range of comple-mentary cables used in installations.
Cavi Potenza e Cavi Speciali
La FCT può offrire al Mercato della Sicurezza una gamma di cavi complementare utilizzati nelle installazioni.

2 x 0,50
2 x 0,75
3 x 0,75
4 x 0,75
2 x 1
3 x 1
2 x 1,5
2 x 2,5
2 x 2 x 1
2 x 2 x 1,5

BUS-CABLE YCYM 2 x 2 x 0,80
Coax TV KTV 1,0

1,02RC/4,6/35% Brading Tin Copper + Al.Pol.Al Foil/6,8 mm
Coax TV KTV 1,0
1,13RC/4,6/35% Brading Tin Copper + Al.Pol.Al Foil/6,8 mm

Mini RG 59

Minicoax
RG 174 Mil C 17 F
RG 59 Mil C 17 F

MENU

 

References RG 174 A/U RG 58 C/U RG 59 B/U Mini RG 59 MiniCoax

Characteristic impedance ( ohm )

Capacitance  ( pF/mt )

Velocity radio ( % )

DC resistance ( at 20°C)

Inner conductor ( ohm/km )

Outer conductor ( ohm/km )

Nominal attenuation

at 47 MHz ( dB/100m )

at 100 MHz ( dB/100m )

at 230 MH ( dB/100m )

at 400 MHz ( dB/100m )

at 800 MHz ( dB/100m )

at 860 MHz ( dB/100m )

at 1000 MHz ( dB/100m )

at 1350 MHz ( dB/100m )

at 1750 MHz ( dB/100m )

at 2050 MHz ( dB/100m )

at 2150 MHz ( dB/100m )

at 2400 MHz ( dB/100m )

Return loss

(30 - 300) MHz ( dB )

(300 - 860) MHz ( dB )

(860 - 2400) MHz ( dB )

Screening efficiency

(30-1350) MHz ( dB )

(1350-2400) MHz ( dB )

Inner inductor ( mm )

Dielectric

Diameter over dielectric  ( mm )

Outer conducter 

Foil

Braid

Coverage ( % )

Antimigrating

Coaxial sheath  ( mm )

Outer sheath

Diam. over outer sheath  ( mm )

Min. bending radius  ( mm )

.

Suggested installations
These cables are available
whit Uleaded PVC sheath

50 ± 3

100

70

.

301

38

.

18,8

27,6

40,9

57,2

81,5

87,5

92,7

.

.

.

.

.

.

>23

>21

.

.

>55

.

CW 7 x 0,16

PE

Ø= 1,52 ± 0,05

.

.

CU-SN Ø = 0,1

85

.

PVC Ø = 2,74 ± 0,1

.

.

15/30

.

Miniaturized cable for data transmission in area with narrow space

 

50 ± 2

98

66

.

38

17

.

10,4

15,1

22,3

33,8

51

52,2

58,8

.

.

.

.

.

.

>35

>30

.

.

>55

.

CU-SN 19x0,18

PE

Ø= 2,95 ± 0,05

.

.

CU-SN

91

.

PVC Ø = 5 ± 0,1

.

.

15/50

.

LAN coaxial cable

75 ± 2

67

66

.

160

9,5

.

7,9

11,2

16,1

23

30,8

32,1

39

.

.

.

.

.

.

>35

>30

.

.

>55

.

CW-Ø = 0,58

PE

Ø= 3,7 ± 0,05

.

.

CU

95

.

PVC Ø = 6,2 ± 0,1

.

.

30/60

.

Data transmission at 75 ohm

 

75 ± 2

67

66

.

6

4,2

.

19,5

28,5

42

60

84

93

102

.

.

.

.

.

.

>35

>30

.

.

>50

.

CW 9x 0,10

PE

Ø= 1,5 ± 0,08

.

.

CU - sn

88

.

PVC Ø = 2,8 ± 0,13

.

.

.

.

Miniaturized cablesuitable for indoorinstallation in areaswith space costraint

 

75 ± 2

56

80

.

6

3,1

.

11

.

28

35

45

47,6

51,2

59,7

69,1

.

76

82

.

>25

>20

.

.

>80

.

CU Ø = 41

PEE/PH

Ø= 1,9 ± 0,05

.

AL

CU Ø = 48 X 0,10

62

.

 Ø = 3,5 ± 0,1

.

.

15/30

.

Miniaturized cablesuitable for indoorinstallation in areaswith space costraint

PE: Polyethylene - PEE: Foamed Polyethylene - PEE/PH: Foamed Polyethylene by Gas injection - PVC: Unleaded Polyethilchloride - LSZH: Low Smoke
Halogen free - AP: Self-supported - AL: Aluminium - CU: Bare Copper - CU-SN: Tinner Copper - CW: Copperweld - CU-AG: Silvered Copper
PET: Polyester foil - CuF: Copper foil - Cu/Pet: Copper+Pet foil - Al/Pet: AL+PET foil - Al/Pet/Al: AL+PET+AL foil - Ø Nominal Diameter

MENU