MENU GENERALE MAIN MENU |
|||||
SECURITY CABLES
Combined
Cables for CCTV - Cavi Combinati per CCTV
Fireproof Cables
- Cavi Antifuoco
Power Cables and Special Cables
- Cavi Potenza e Cavi Speciali
RG
174 A/U - RG
58 C/U - RG
59 B/U - Mini RG 59 - MiniCoax
|
|
|
Alarm Cables |
Cavi Allarme |
| Type Section / Sezione * |
Core / Conduttore mm * |
Insulation
/ Isolamento mm * |
Outside
diam. / Diametro Totale * ( mm ) |
||
| ( *Nominal value / Valori Nominali ) | 300 / 300 V | 450 / 750 V | 0,6 / 1 KV | ||
| PVC / PVC | |||||
|
2 x 0,22
|
7 x 0,20 |
0,23 |
3,3 |
3,6 |
3,8 |
| LSZH | |||||
| Type Section / Sezione * |
Core / Conduttore mm * |
Insulation
/ Isolamento mm * |
Outside
diam. / Diametro Totale * ( mm ) |
||
| ( *Nominal value / Valori Nominali ) | 300 / 300 V | 450 / 750 V | 0,6 / 1 KV | ||
|
4 x 0,22 6 x 0,22 8 x 0,22 10 x 0,22 4 x 20 AWG 6 x 20 AWG 8 x 20 AWG 10 x 20 AWG |
7 x 0,20 7 x 0,20 7 x 0,20 7 x 0,20 5 / 10 5 / 10 5 / 10 5 / 10 |
0,23 0,23 0,23 0,23 0,25 0,25 0,25 0,25 |
3,3 3,5 4,2 4,6 4,2 4,8 5 5,9 |
3,6 4,2 5 5,5 |
3,8 5 5,5 6 |
| Combined Cables for CCTV Our combined cables are produced according to the technical specifications required by the Institutes of Telesurveillance and the product range that FCT can supply at currently manufactu-red standards is as follows: |
Cavi Combinati per CCTV I nostri cavi combinati sono prodotti secondo le specifiche tecniche richieste dagli Istituti di Telesorveglianza e la gamma che la FCT può offrire negli standards attualmente prodotti é la seguente: |
|
Mini Rg 59 + ( 2 x 0,75 + 2 x 0,22 ) |
MiniCoax + 2 x 0,75 |
| Fireproof Cables FTC can cater to clients’ needs in producing security cables which are fire resistant for use in firefighting plants, both with copper-mica and copper sheet shielding and fibreglass covering. These cables are produced to work between 30 and 180 minutes in the presence of fire. |
Cavi Antifuoco FTC é in grado di produrre, su richiesta del Cliente, cavi di sicurezza resistenti al fuoco per centrali antincendio, prodotti sia con rame-mica e sia con schermatura con foglio di rame e ricopertura in fibra di vetro. Questi cavi sono prodotti, secondo la tipologia, per funzionare da 30 a 180 minuti in ambienti con presenza di fuoco. |
| Power Cables and Special Cables FTC can supply the Security Market with a range of comple-mentary cables used in installations. |
Cavi Potenza e Cavi Speciali La FCT può offrire al Mercato della Sicurezza una gamma di cavi complementare utilizzati nelle installazioni. |
|
2 x 0,50 |
BUS-CABLE YCYM 2 x 2 x 0,80 |
|
|
|
|
|
|
| References | RG 174 A/U | RG 58 C/U | RG 59 B/U | Mini RG 59 | MiniCoax |
|
Characteristic impedance ( ohm ) Capacitance ( pF/mt ) Velocity radio ( % ) DC resistance ( at 20°C) Inner conductor ( ohm/km ) Outer conductor ( ohm/km ) Nominal attenuation at 47 MHz ( dB/100m ) at 100 MHz ( dB/100m ) at 230 MH ( dB/100m ) at 400 MHz ( dB/100m ) at 800 MHz ( dB/100m ) at 860 MHz ( dB/100m ) at 1000 MHz ( dB/100m ) at 1350 MHz ( dB/100m ) at 1750 MHz ( dB/100m ) at 2050 MHz ( dB/100m ) at 2150 MHz ( dB/100m ) at 2400 MHz ( dB/100m ) Return loss (30 - 300) MHz ( dB ) (300 - 860) MHz ( dB ) (860 - 2400) MHz ( dB ) Screening efficiency (30-1350) MHz ( dB ) (1350-2400) MHz ( dB ) Inner inductor ( mm ) Dielectric Diameter over dielectric ( mm ) Outer conducter Foil Braid Coverage ( % ) Antimigrating Coaxial sheath ( mm ) Outer sheath Diam. over outer sheath ( mm ) Min. bending radius ( mm ) . Suggested installations |
50 ± 3 100 70 . 301 38 . 18,8 27,6 40,9 57,2 81,5 87,5 92,7 . . . . . . >23 >21 . . >55 . CW 7 x 0,16 PE Ø= 1,52 ± 0,05 . . CU-SN Ø = 0,1 85 . PVC Ø = 2,74 ± 0,1 . . 15/30 . Miniaturized cable for data transmission in area with narrow space
|
50 ± 2 98 66 . 38 17 . 10,4 15,1 22,3 33,8 51 52,2 58,8 . . . . . . >35 >30 . . >55 . CU-SN 19x0,18 PE Ø= 2,95 ± 0,05 . . CU-SN 91 . PVC Ø = 5 ± 0,1 . . 15/50 . LAN coaxial cable |
75 ± 2 67 66 . 160 9,5 . 7,9 11,2 16,1 23 30,8 32,1 39 . . . . . . >35 >30 . . >55 . CW-Ø = 0,58 PE Ø= 3,7 ± 0,05 . . CU 95 . PVC Ø = 6,2 ± 0,1 . . 30/60 . Data transmission at 75 ohm
|
75 ± 2 67 66 . 6 4,2 . 19,5 28,5 42 60 84 93 102 . . . . . . >35 >30 . . >50 . CW 9x 0,10 PE Ø= 1,5 ± 0,08 . . CU - sn 88 . PVC Ø = 2,8 ± 0,13 . . . . Miniaturized cablesuitable for indoorinstallation in areaswith space costraint
|
75 ± 2 56 80 . 6 3,1 . 11 . 28 35 45 47,6 51,2 59,7 69,1 . 76 82 . >25 >20 . . >80 . CU Ø = 41 PEE/PH Ø= 1,9 ± 0,05 . AL CU Ø = 48 X 0,10 62 . Ø = 3,5 ± 0,1 . . 15/30 . Miniaturized cablesuitable for indoorinstallation in areaswith space costraint |
|
PE: Polyethylene - PEE: Foamed Polyethylene -
PEE/PH: Foamed Polyethylene by Gas injection - PVC: Unleaded Polyethilchloride -
LSZH: Low Smoke Halogen free - AP: Self-supported - AL: Aluminium - CU: Bare Copper - CU-SN: Tinner Copper - CW: Copperweld - CU-AG: Silvered Copper PET: Polyester foil - CuF: Copper foil - Cu/Pet: Copper+Pet foil - Al/Pet: AL+PET foil - Al/Pet/Al: AL+PET+AL foil - Ø Nominal Diameter |
|||||